Evaluation of positioning and density profiling accuracy of muon radiography by utilizing a 15-ton steel block

Tanaka, H. K. M.

A model experiment was performed in order to evaluate the spatial resolution and the accuracy of determining the density by utilizing a steel block. The steel block (7.8 g cm −3) is 5 m thick along the muon trajectories and weighs about 15 t. By comparing the experimental result with simulations, the density and the width of the steel block were measured as 7.3 ± 1.0 g cm −3 and 37 ± 15 cm, respectively.

Zitieren

Zitierform:

Tanaka, H. K. M.: Evaluation of positioning and density profiling accuracy of muon radiography by utilizing a 15-ton steel block. 2013. Copernicus Publications.