Can ozone be used to calibrate aerosol photoacoustic spectrometers?

Fischer, D. Al; Smith, Geoffrey D.

Photoacoustic spectroscopy (PAS) has become a popular technique for measuring absorption of light by atmospheric aerosols in both the laboratory and field campaigns. It has low detection limits, measures suspended aerosols, and is insensitive to scattering. But PAS requires rigorous calibration to be applied quantitatively. Often, a PAS instrument is either filled with a gas of known concentration and absorption cross section, such that the absorption in the cell can be calculated from the product of the two, or the absorption is measured independently with a technique such as cavity ring-down spectroscopy. Then, the PAS signal can be regressed upon the known absorption to determine a calibration slope that reflects the sensitivity constant of the cell and microphone. Ozone has been used for calibrating PAS instruments due to its well-known UV–visible absorption spectrum and the ease with which it can be generated. However, it is known to photodissociate up to approximately 1120 nm via the inline-formulaO3inline-formula+inline-formula M3inlinescrollmathml h italic ν nobreak0.25em ( > normal 1.1 normal eV ) chem normal O normal 2 ( normal 3 normal Σ g - ) 117pt17ptsvg-formulamathimg2540a17128385cdeb672d3ea6820a4f8 amt-11-6419-2018-ie00001.svg117pt17ptamt-11-6419-2018-ie00001.png inline-formula+inline-formulaO(3P) pathway, which is likely to lead to inaccuracies in aerosol measurements. Two recent studies have investigated the use of inline-formulaO3 for PAS calibration but have reached seemingly contradictory conclusions with one finding that it results in a sensitivity that is a factor of 2 low and the other concluding that it is accurate. The present work is meant to add to this discussion by exploring the extent to which inline-formulaO3 photodissociates in the PAS cell and the role that the identity of the bath gas plays in determining the PAS sensitivity. We find a 5 % loss in PAS signal attributable to photodissociation at 532 nm in inline-formulaN2 but no loss in a 5 % mixture of inline-formulaO2 in inline-formulaN2. Furthermore, we discovered a dramatic increase of more than a factor of 2 in the PAS sensitivity as we increased the inline-formulaO2 fraction in the bath gas, which reached an asymptote near 100 % inline-formulaO2 that nearly matched the sensitivity measured with both inline-formulaNO2 and nigrosin particles. We interpret this dependence with a kinetic model that suggests the reason for the observed results is a more efficient transfer of energy from excited inline-formulaO3 to inline-formulaO2 than to inline-formulaN2 by a factor of 22–55 depending on excitation wavelength. Notably, the two prior studies on this topic used different bath gas compositions, and although the results presented here do not fully resolve the differences in their results, they may at least partially explain them.

Zitieren

Zitierform:

Fischer, D. Al / Smith, Geoffrey D.: Can ozone be used to calibrate aerosol photoacoustic spectrometers?. 2018. Copernicus Publications.

Zugriffsstatistik

Gesamt:
Volltextzugriffe:
Metadatenansicht:
12 Monate:
Volltextzugriffe:
Metadatenansicht:

Grafik öffnen

Rechte

Rechteinhaber: D. Al Fischer

Nutzung und Vervielfältigung:

Export